The Characteristics of Absorbency Under Load (AUL) for Superabsorbent and Soil Mixtures

The Characteristics of Absorbency Under Load (AUL) for Superabsorbent and Soil Mixtures


Play all audios:

Loading...

Download PDF Article Open access Published: 02 December 2019 The Characteristics of Absorbency Under Load (AUL) for Superabsorbent and Soil Mixtures Jakub Misiewicz  ORCID:


orcid.org/0000-0002-5007-60681, Krzysztof Lejcuś  ORCID: orcid.org/0000-0001-5440-98541, Jolanta Dąbrowska2 & …Daria Marczak1 Show authors Scientific Reports volume 9, Article number: 18098


(2019) Cite this article


5278 Accesses


29 Citations


Metrics details

Subjects Environmental chemistryEnvironmental impactEnvironmental sciences Abstract


Various applications of superabsorbent polymers (SAP) include the use of these materials in agriculture and environmental engineering to increase soil water retention. Under such conditions,


there is water absorption of the SAP in soil under load. This paper presents the results of absorbency under load (AUL) of a cross-linked copolymer of acrylamide and potassium acrylate


mixed at ratios of 0.3%, 0.5% and 1.0% with coarse sand and sandy loam. The mixtures were subjected to loads equivalent to 10, 20 and 40 cm of soil. The highest differences in AUL values for


both soils, compared to the control sample, were obtained after 24 hours and at a maximum load of 5.9 kPa, which corresponds to a load of a 40 cm thick topsoil layer. The AUL was 71.4 g∙g−1


for coarse sand and 52.7 g∙g−1 for sandy loam with a 1.0% SAP addition, which corresponded to 24.0% and 18.0%, respectively, of the absorption in the control sample. All the conducted tests


revealed a significantly low rate of water absorbency, which is especially important for capturing the water that infiltrates into the soil profile. The results demonstrate that water


absorption by SAPs decreased with the increase in SAP addition.

Similar content being viewed by others Enhancement of sandy soil water retention using superabsorbent carboxymethyl


cellulose grafted with polyacrylamide and polyacrylamidomethyl propanesulfonic acid copolymer Article Open access 13 May 2025 Impact of polyacrylic acid as soil amendment on soil microbial


activity under different moisture regimes Article Open access 03 June 2025 Design and manufacturing of superabsorbent polymers (SAPs) for agriculture in arid areas Article Open access 09 May


2025 Introduction


SAPs are crosslinked polymer networks with strong hydrophilic groups that can be tailored to meet specific parameters of water absorption, depending on the composition1,2. The loosely


cross-linked structure of SAPs and their capability to absorb water and its solutions in amounts several hundred times higher than their dry mass have attracted much attention in recent


years3,4,5,6. Because the absorption capacity of SAPs exceeds that of conventional products, SAPs are widely used in medicine, the manufacturing of personal care products, water treatment,


food storage, environmental engineering, forestry, and a variety of agricultural and urban greenery applications as soil conditioning agents7,8,9,10,11,12,13,14. The function of SAPs in the


soil is to absorb water from rainfall or irrigation systems and then gradually release it to plants to support their growth and enhance their quality15. Chemical crosslinks prevent the


dissolution of SAPs in water during the swelling process16,17. Because they do not become hydrophobic during droughts, these materials may support water retention and improve the water


retention capacity (WRC) of sandy soils and permeable soils much more efficiently than can humic substances18. As a result, SAPs are characterized by properties that enable them to support


vegetation growth and reduce evaporation and leaching of fertilizers and protective agents in areas with limited irrigation opportunities, where irrigation is necessary to support plant


development and reduce water stress19,20,21. The water absorbed by SAPs may be supplied to plants by suction forces of the roots, so even up to 95% of the water can be used22. Water


absorption by SAPs in soil depends on several factors, including soil structure, saline content, temperature, pH, moisture content, and presence of microorganisms, as well as soil wetting


and drying cycles23. On the other hand, in terms of surface performance characteristics, the amendment type does have a significant effect on certain soil parameters, e.g., shear strength,


soil structure and total soil porosity24,25,26,27,28.


Considering the target application of SAPs, the swelling kinetics of the absorption process is very important. When the SAPs are submerged in water, the water diffuses into the polymer


matrix, and the material starts swelling. The water continues to migrate to the dynamically emerging spaces between macromolecular chains until the equilibrium state is achieved29. The water


transport in SAPs is Fickian in nature30. As far as SAPs are concerned, the spring and dashpot Voight-based viscoelastic model is best known and most often applied for use in modeling creep


and relaxation31,32,33.


The most commonly used way of introducing SAPs into soil is mechanical mixing with soil at the required depth34. Regardless of the manner of introduction to the soil, the SAP will swell


under loading and in a limited space. The topsoil layer load directly influences the reduced absorption capacity35,36.


However, so far, few studies have been conducted that describe the characteristics of the interactions between SAPs and soil. The external load and the swelling capability of SAPs in porous


regions of the soil have a direct influence on the SAP’s water absorption capacity. The described results of absorbency under load (AUL) either include the basic parameters of synthesized


SAPs or refer to their applications in personal care products31,32,33,37. The results of these studies do not reflect the characteristics of SAP swelling in soil and thus cannot be


representative of applications in environmental engineering and agriculture.


The main objective of the present research project is to provide an analysis of the SAP liquid absorption in soil mixtures under loads corresponding to various topsoil layer thicknesses. The


authors prepared mixtures of SAPs and soils of various densities and at various ratios. The mixtures were subjected to additional loads with solid weights that simulated upper soil layers


of various thicknesses. The objective of the study was to describe the process of SAP swelling in time in conditions similar to the actual applications in environmental engineering and


agriculture.

Materials and MethodsMaterials


A cross-linked copolymer of acrylamide and potassium acrylate – Aquasorb 3005 KL (SNF FLOERGER, Andrézieux, France) was used in this study. The SAP used in the experiments was in the form of


dry, irregularly shaped granules. The SAP-soil mixture was prepared using two types of soil: coarse sand and sandy loam. The samples were collected from the upper soil horizon (0–30 cm) at


the Experimental Field Station of the Wrocław University of Environmental and Life Sciences in Swojec (51°06′58″N 17°08′26″E).

SAPs and physical characteristics of the soils


The grain size distribution of the SAPs and soils used was determined by the sieving method. A total of 500 g of dry material was sieved by pouring onto a sequence of 6 sieves with mesh


widths of 0.10, 0.25, 0.50, 1.00, 2.00, and 5.00 mm. Soils that contained finer particles were subjected to hydrometer analysis. The tests were repeated 3 times for each material, and the


results were averaged. Soil bulk densities were determined by the bulk density test, in which the weight and volume of the soil sample were measured after being dried in the oven. Soil


organic matter (SOM) was determined as percentage weight loss before and after burning in a 400 °C furnace. As a result, grain size distribution curves with a range of grains were created.


The soil parameters are presented in Table 1. The tested soils were classified according to the USDA classification.

Table 1 Physical characteristics of soils and SAP.Full size tableAUL


measurement procedure


The tests were based on the measurement concept developed by Ramazani- Harandi et al.38 and were modified by Lejcuś et al.35. Tests of AUL were conducted in a Multitest 2.5-xt apparatus


manufactured by Mecmesin. A mixture of dry soil (200 g) with SAP in predefined proportions (0.30%, 0.50%, 1.00%) was prepared separately for each test. The SAP was manually mixed with the


soil in a container using a mixer until a homogeneous mixture was obtained. A set of Plexiglas cylinders was prepared for the tests. The SAP-soil mixture was placed in the internal cylinder


with a porous bottom (d = 70.00 mm) and subjected to the cylindrical solid load (d = 68.00 mm) of a weight corresponding to the upper soil layer thickness. The whole set was then placed in


the external cylinder (d = 80.00 mm) on the tray of the apparatus. Afterwards, distilled water at a temperature of 23 °C was added to the external cylinder through a droplet system. The


water level in the external cylinder was regulated to reach the height of the sample to ensure full saturation for the duration of the experiment. The amount of water during the tests was


also controlled to prevent the hydraulic pressure from influencing the sensor device. In the experiment, the SAP-soil mixture was placed under a cylindrical solid load with a weight


corresponding to layers of soil with a bulk density of 1.50 g/cm3 and heights of 10.00, 20.00, and 40.00 cm. The weights were converted into kPa. These heights correspond to the typical


layers of covers of earth structures or to those layers used when planting trees and bushes. The experiment was repeated three times for each SAP-soil mixture-load configuration. The results


were averaged.


The load caused by the soil layer was calculated using the following equation:

$${\rm{\upsilon }}={\rm{\rho }}\cdot {\rm{g}}\cdot {\rm{h}}[P{\rm{a}}]$$ (1)


where υ is the soil load [Pa], ρ is the bulk density of the overlying soil [kg∙ m−3], g is the acceleration due to gravity [m∙s−2], and h is the soil layer height [m].


The changes in sample height were measured by an apparatus sensor for 24 hours and plotted as displacement over time. To simulate the soil load, the cylindrical metal weights were placed on


top of the SAP-soil mixture so as to prevent rubbing against the walls of the cylinder. Measurements were taken with the use of a force sensor (ICL) with an accuracy of ±0.10%. During


swelling under load, the sample put pressure on the ICL force sensor. When the force measured by the sensor reached 0.20N, the sensor moved up until the force was reduced to 0.00N. The


displacement of the sensor and increase in force were measured at a frequency of 10 Hz by the controlling software Emperor™ (version 1.18-305, Mecmesin Ltd., Slinfold, United Kingdom). This


procedure allowed us to measure the increase in sample height and the time of swelling of the SAP. Additional tests were conducted using pure SAP without load as a control sample. The


drawing of the apparatus with the experimental setup is presented in Fig. 1.

Figure 1


Test apparatus (Mecmesin multitest-2.5xt) with the experimental setup. (1) ICL Force sensor, (2) droplet system, (3) outer cylinder with water, (4) inner cylinder with porous bottom, (5)


load, (6) SAP-soil mixture.

Full size image


The measured increase in sample height was converted into swelling value [g∙g−1]. The test series were conducted in the same way. AUL was calculated according to the following formula


(2)38:

$${\rm{AUL}}=\frac{{\rm{W}}2-{\rm{W}}1}{{\rm{W}}1}$$ (2)


where AUL [g∙g−1] is absorbency under load, and W1 [g] and W2 [g] are the weights of the swollen SAP and dry SAP, respectively.


The data were processed using the Voight-based model, and the swelling rate of the SAP was described by the following Eq.


(3)32,33:

$${{\rm{S}}}_{{\rm{t}}}={{\rm{S}}}_{{\rm{e}}}(1-{e}^{-\frac{t}{\tau }})$$ (3)


where St [g∙g−1] is the swelling at time t, Se [g∙g−1] is the equilibrium swelling (power parameter, absorption capacity), t [min] is the time of swelling, and τ [min] is the time parameter


(time required to reach 63% of the maximum absorption capacity).


Using the Voight-based model, the rate parameter (τ) and equilibrium swelling (Se) were calculated for each load-ratio configuration.


Statistical analyses were conducted to determine the statistical significance of the obtained swelling results of SAP-soil mixtures under load. The equality of variances was calculated using


the Levene test.


The statistical groups (different loads and SAP-soil proportions) for both soils used were compared with the control group (without load or soil) by performing Dunnett’s C test (post hoc


group comparison). The level of significance was set at 0.05 for each group (n = 9). Data analysis and curve fitting were conducted using Statistica software (version 13.0, StatSoft, Kraków,


Poland) and Microsoft Excel (version 2007, Microsoft Corporation, Redmont, USA).

ResultsPhysical characteristics of soils and SAPs


The characteristics of grain size distribution need to be evaluated to determine the correct methods for swelling capacity characterization. The most important property of SAPs, i.e., their


absorption capacity, is directly linked to particle size and degree of cross-linking39. The grain size distribution of soils is also important from the point of view of preparing SAP-soil


mixtures. The grain size distributions of the analyzed soils and SAP is presented in Fig. 2. For Aquasorb 3005 KL, particles from the 0.50–1.00 mm range account for the highest share (over


36%), followed by the 1.00–2.00 mm particles (35.00%). For coarse sand, the highest share was noted for the 1.00–2.00 mm particles (over 62.00%), while particles in the 0.50–1.00 mm range


accounted for more than 35%. Sandy loam was characterized by the most differentiated particle sizes. The ranges of 0.50–1.00 mm, 0.25–050 mm and 0.10–0.25 accounted for 21.00%, 19.00% and


18.00%, respectively.

Figure 2


Grain size distributions of the tested SAP and soil.

Full size imageAUL and swelling kinetics


The obtained values of the rate parameter (τ) and equilibrium swelling (Se) for the tested SAP-soil mixtures under various loads are presented in Table 2, and the curves fitted to the


swelling process are shown in Figs. 3 and 4.

Table 2 Rate parameter (τ) and equilibrium swelling (Se) for the tested SAP.Full size tableFigure 3


Time-dependent absorption under load for SAP and sandy loam mixtures, under (a) 10.00, (b) 20.00, and (c) 40.00 cm thick soil layer with bulk density of 1.5 g∙cm−3 (error bars: standard


deviations).

Full size imageFigure 4


Time-dependent absorption under load for SAP and coarse sand mixtures under (a) 10.00, (b) 20.00, and (c) 40.00 cm thick soil layer with a bulk density of 1.50 g∙cm−3 (error bars: standard


deviations).

Full size image


The analysis of results demonstrated that the assumptions for parametric tests (variance equality and normal distribution) were not fulfilled. The non-parametric Dunnett’s C test was


conducted to compare individual groups with the control group. The results revealed that all variants of the experiment (different loads and SAP-soil proportions) differed substantially from


the control samples.


The results prove that load has a noticeable influence on the reduction in swelling of SAP-soil mixtures. Regardless of the applied load and the proportion in which the SAP was mixed with


soil, the differences in water absorption compared to those in free swelling are significant (Table 2; Figs. 3 and 4).


The highest differences in the AUL values compared to the control samples after 1440 min, for both coarse sand and sandy loam, were obtained for the pressure of 5.89 kPa, which corresponds


to a load of topsoil layer thickness of 40.00 cm (bulk density of 1.50 g∙cm−3) (Figs. 3 and 4). In this variant, the obtained AUL values were 71.40 g∙g−1 for coarse sand and 52.70 g∙g −1 for


sandy loam (1.00% SAP), which account for over 24.00% and nearly 18.00%, respectively, in comparison to the control group. The load affects not only the AUL but also the swelling kinetics.


A sample of SAP-coarse-sand mixture (1.00%) subjected to a load of 5.89 kPa reached an AUL of 16.30 g∙g−1 after the first 30 min of the experiment, while it took the control sample only 3 


min to reach this value. For the same load and the proportion of 0.50% in the SAP-sandy-loam mixture, the AUL after 30 min was 11.70 g∙g−1, while the control sample achieved this value after


only 2 min.


The highest AUL values were noted for samples loaded with a 10 cm soil layer (1.47 kPa), where the share of SAP in the mixture was the lowest (0.30%) (Figs. 3 and 4). The maximum AUL values


in this configuration were 100.30 g∙g −1 for coarse sand and 96.50 g∙g −1 for sandy loam. Although the AUL results for both soils were similar, the swelling rates differed. The


SAP-sandy-loam sample took 220 min to reach 90.00% of the total AUL, while the SAP-coarse-sand mixture sample needed only 130 min. Regardless of the type of soil, the proportions of SAP in


the mixture and of the external load, the amount of retained water and the absorption rate were significantly lower than those in the control group. The difference in absorption under load


between the SAP-sandy-loam mixture (0.50%) subjected to a load of 5.89 kPa and the control sample without load exceeds 1200.00%. The lowest variability of the differences in absorption was


noted for the smallest load of the coarse sand sample (0.30%), which equaled approx. 300.00% for the entire duration of the experiment. To obtain the maximum efficiency of water absorption


by the SAP-soil mixture, one should take into account the share of SAP in the mixture and the thickness of the layer with which it will be loaded.

Discussion


The tests of SAP in terms of their capacity to absorb water and its solutions are based on various methodological approaches and usually consist of two main types: water absorbency tests,


where the SAP is directly mixed with soil, and tests of absorbency under load, where the SAP is subjected to additional load. The present study combines both these approaches and focuses on


analyzing the absorbency under load for SAP-soil mixtures at various proportions to obtain the actual values of water absorption by the given SAP under a specific load. The comparison of


experiments conducted on SAP-soil mixtures in various proportions reveals that the water absorption by the SAPs decreased with the increase in SAP addition20,40,41,42. In cases where this


correlation is not true, the differences in water absorbency are low and reach only approx. 5.00%43. On the other hand, experiments conducted on SAP samples subjected to direct load confirm


the influence of load on the absorption value. However, in this approach, the type of absorbed substance is an important factor. The results of the present experiment and of others conducted


with use of DI water demonstrate that the AUL decreases significantly with the increase in load35, while tests on the absorption of saline solutions yielded less varied results, although


the differences in the load of the sample were three times higher36,44. Although numerous studies on various SAP polymers have been conducted, the comparison of results still poses a


problem. Due to the differences in the methodologies used by the authors, the conditions of the experiments and the use of various types of SAPs in various doses, the differences in the


results are often significant and prevent a direct comparison of the obtained results. Table 3 presents the results obtained by other authors that take into account the SAP addition in


SAP-soil mixtures. Table 4 presents the results obtained by other authors that take into account the absorbency under load. The values of load, SAP addition, and water absorbency have been


converted to the same units.

Table 3 Comparison of water absorbency results for practical applications of SAPs with various soil additions.Full size tableTable 4 Comparison of water


absorbency results for practical applications of SAPs under various loads.Full size table


In spite of the differences mentioned before, the results obtained by the authors of this study are similar to those obtained by other authors. The addition of SAPs to soils improves the


retention of water, which may be used by plants. However, the water absorbency values decrease with the increase in the SAP-soil ratio, which should be considered when choosing the dosage of


SAP. Another important parameter is the influence of the external load, which directly limits the absorption volume. The conducted research confirmed that tests of SAP-soil mixtures result


in higher AUL values than tests of SAP without subjecting the soil to load. This difference results from the swelling of single grains of SAP in soil pores. In this way, the conducted


research reflected the interaction between SAP and soil with which the material is mixed and additionally loaded with an external layer. The obtained results also illustrate the necessity to


consider the influence of soil load on the SAP and the resulting water absorbency reduction and rate if SAPs are used as a means to improve soil water retention. This problem may be solved


by enabling the SAPs to absorb water in the soil medium without the influence of the load of a layer of soil, e.g., in the form of water-absorbing geocomposites, whose structure provides the


SAPs with sufficient space to swell freely45.

Conclusions


The conducted research confirmed that both AUL and SAP content are important parameters that determine water absorbency by SAPs in soil medium, which in turn is reflected in the efficiency


of their use in environmental engineering and agriculture. The main factors that affect water absorbency by SAPs are the depth of application and soil bulk density, which determine the


influence of load on the SAP and the amount of its addition to soil. The obtained results show that the effectiveness of SAP application into soil may be estimated based on the results of


water absorbency of SAP-soil mixtures. In the conducted tests, the differences in the amount of water retained (absorbed) by the SAP mixed with soil, for the analyzed maximum load 5.89 kPa,


exceed 1200% in comparison to the control sample. Soil load not only limits water absorption by the SAP, but it also delays swelling time, which is important if the superabsorbent is applied


as an additive to improve soil water retention. The obtained results confirm the need to reconsider the manner of introducing SAPs into the soil. These results also indicate the need to


specify the depth of application and the manner of introducing SAPs to soil in the descriptions of field and laboratory tests.


References Zhang, B., Cui, Y., Yin, G., Li, X. & You, Y. Synthesis and Swelling Properties of Hydrolyzed Cottonseed Protein Composite Superabsorbent Hydrogel. Int. J. Polym. Mater. 59,


1018–1032 (2010).


Article  CAS  Google Scholar 


Puoci, F. et al. Polymer in Agriculture: a Review. Am. J. Agric. Biol. Sci. 3, 299–314 (2008).


Article  Google Scholar 


Bajpai, S. K. & Johnson, S. Superabsorbent hydrogels for removal of divalent toxic ions. Part I: Synthesis and swelling characterization. React. Funct. Polym. 62, 271–283 (2005).


Article  CAS  Google Scholar 


Abd El-Rehim, H. A. Swelling of radiation crosslinked acrylamide-based microgels and their potential applications. Radiat. Phys. Chem. 74, 111–117 (2005).


Article  ADS  CAS  Google Scholar 


Liu, Z., Miao, Y., Wang, Z. & Yin, G. Synthesis and characterization of a novel super-absorbent based on chemically modified pulverized wheat straw and acrylic acid. Carbohydr. Polym. 77,


131–135 (2009).


Article  CAS  Google Scholar 


Aloulou, F., Boufi, S. & Labidi, J. Modified cellulose fibres for adsorption of organic compound in aqueous solution. Sep. Purif. Technol. 52, 332–342 (2006).


Article  CAS  Google Scholar 


Chen, Z., Liu, M. & Qi, X. Synthesis and Properties of a Superabsorbent Polymer Prepared by Copolymerization of Sodium Acrylate with Sodium 1-(Acryloyloxy)propan-2-yl Phosphate. Macromol.


React. Eng. 1, 275–283 (2007).


Article  CAS  Google Scholar 


Zohuriaan-Mehr, M. J., Omidian, H., Doroudiani, S. & Kabiri, K. Advances in non-hygienic applications of superabsorbent hydrogel materials. J. Mater. Sci. 45, 5711–5735 (2010).


Article  ADS  CAS  Google Scholar 


Islam, M. R. et al. A lysimeter study of nitrate leaching, optimum fertilisation rate and growth responses of corn (Zea mays L.) following soil amendment with water-saving super-absorbent


polymer. J. Sci. Food Agric. 91, 1990–1997 (2011).


Article  CAS  PubMed  Google Scholar 


Hüttermann, A., Zommorodi, M. & Reise, K. Addition of hydrogels to soil for prolonging the survival of Pinus halepensis seedlings subjected to drought. Soil Tillage Res. 50, 295–304 (1999).


Article  Google Scholar 


Shah, L. A. et al. Superabsorbent polymer hydrogels with good thermal and mechanical properties for removal of selected heavy metal ions. J. Clean. Prod. 201, 78–87 (2018).


Article  CAS  Google Scholar 


Szewrański, S. et al. Pluvial Flood Risk Assessment Tool (PFRA) for rainwater management and adaptation to climate change in newly urbanised areas. Water (Switzerland) 10 (2018).


Article  Google Scholar 


Snoeck, D., Pel, L. & De Belie, N. The water kinetics of superabsorbent polymers during cement hydration and internal curing visualized and studied by NMR. Sci. Rep. 7, 9514 (2017).


Article  ADS  CAS  PubMed  PubMed Central  Google Scholar 


Capezza, A. J., Newson, W. R., Olsson, R. T., Hedenqvist, M. S. & Johansson, E. Advances in the Use of Protein-Based Materials: Toward Sustainable Naturally Sourced Absorbent Materials. ACS


Sustain. Chem. Eng. 7, 4532–4547 (2019).


Article  CAS  Google Scholar 


Laftah, W. A., Hashim, S. & Ibrahim, A. N. Polymer Hydrogels: A Review. Polym. Plast. Technol. Eng. 50, 1475–1486 (2011).


Article  CAS  Google Scholar 


Wei, Q.-B., Luo, Y.-L., Fu, F., Zhang, Y.-Q. & Ma, R.-X. Synthesis, characterization, and swelling kinetics of pH-responsive and temperature-responsive carboxymethyl chitosan/polyacrylamide


hydrogels. J. Appl. Polym. Sci. 129, 806–814 (2013).


Article  CAS  Google Scholar 


Wei, Q.-B., Luo, Y.-L., Gao, L.-J., Wang, Q. & Wang, D.-J. Synthesis, characterization and swelling kinetics of thermoresponsive PAM-g-PVA/PVP semi-IPN hydrogels. Polym. Sci. Ser. A 53,


707–714 (2011).


Article  CAS  Google Scholar 


Zhao, W., Cao, T., Dou, P., Sheng, J. & Luo, M. Effect of various concentrations of superabsorbent polymers on soil particle-size distribution and evaporation with sand mulching. Sci. Rep.


9, 3511 (2019).


Article  ADS  PubMed  PubMed Central  CAS  Google Scholar 


Lejcuś, K., Dąbrowska, J., Garlikowski, D. & Śpitalniak, M. The application of water-absorbing geocomposites to support plant growth on slopes. Geosynth. Int. 22, 452–456 (2015).


Article  Google Scholar 


Abedi-Koupai, J., Sohrab, F. & Swarbrick, G. Evaluation of Hydrogel Application on Soil Water Retention Characteristics. J. Plant Nutr. 31, 317–331 (2008).


Article  CAS  Google Scholar 


Buchholz, F. L. & Graham, A. T. Modern superabsorbent polymer technology. (Wiley-VCH, 1998).


Wei, Y. & Durian, D. J. Effect of hydrogel particle additives on water-accessible pore structure of sandy soils: A custom pressure plate apparatus and capillary bundle model. Phys. Rev. E


87, 053013 (2013).


Article  ADS  CAS  Google Scholar 


Bai, W., Song, J. & Zhang, H. Repeated water absorbency of super-absorbent polymers in agricultural field applications: a simulation study. Acta Agric. Scand. Sect. B - Soil Plant Sci. 63,


433–441 (2013).


CAS  Google Scholar 


Hejduk, S., Baker, S. W. & Spring, C. A. Evaluation of the effects of incorporation rate and depth of water-retentive amendment materials in sports turf constructions. Acta Agric. Scand.


Sect. B — Soil Plant Sci. 62, 155–164 (2012).


Google Scholar 


Frantz, J. M., Locke, J. C., Pitchay, D. S. & Krause, C. R. Actual performance versus theoretical advantages of polyacrylamide hydrogel throughout bedding plant production. HortScience 40,


2040–2046 (2005).


Article  Google Scholar 


Syvertsen, J. P. & Dunlop, J. M. Hydrophilic gel amendments to sand soil can increase growth and nitrogen uptake efficiency of citrus seedlings. HortScience 39, 267–271 (2004).


Article  CAS  Google Scholar 


Han, Y. G. et al. Porosity change model for watered super absorbent polymer-treated soil. Environ. Earth Sci. 61, 1197–1205 (2010).


Article  CAS  Google Scholar 


Yang, Y. et al. Assessment of the responses of soil pore properties to combined soil structure amendments using X-ray computed tomography. Sci. Rep. 8, 695 (2018).


Article  ADS  PubMed  PubMed Central  CAS  Google Scholar 


Witono, J. R., Noordergraaf, I. W., Heeres, H. J. & Janssen, L. P. B. M. Water absorption, retention and the swelling characteristics of cassava starch grafted with polyacrylic acid.


Carbohydr. Polym. 103, 325–332 (2014).


Article  CAS  PubMed  Google Scholar 


Hüttermann, A., Orikiriza, L. J. B. & Agaba, H. Application of Superabsorbent Polymers for Improving the Ecological Chemistry of Degraded or Polluted Lands. CLEAN - Soil, Air, Water 37,


517–526 (2009).


Article  CAS  Google Scholar 


Omidian, H., Hashemi, S. A., Sammes, P. G. & Meldrum, I. A model for the swelling of superabsorbent polymers. Polymer (Guildf). 39, 6697–6704 (1998).


Article  CAS  Google Scholar 


Pourjavadi, A., Eftekhar Jahromi, P., Seidi, F. & Salimi, H. Synthesis and swelling behavior of acrylatedstarch-g-poly (acrylic acid) and acrylatedstarch-g-poly (acrylamide) hydrogels.


Carbohydr. Polym. 79, 933–940 (2010).


Article  CAS  Google Scholar 


Sadeghi, M. & Hosseinzadeh, H. Synthesis and swelling behavior of starch-poly(sodium acrylate-co-acrylamide) superabsorbent hydrogel. Turk. J. Chem. 32, 375–388 (2008).


CAS  Google Scholar 


Ptach, W., Boczoń, A. & Wróbel, M. The use of hydrogel in afforestation of postindustrial areas. J. Water L. Dev. 13b, 125–135 (2009).


Google Scholar 


Lejcuś, K., Śpitalniak, M. & Dabrowska, J. Swelling behaviour of superabsorbent polymers for soil amendment under different loads. Polymers (Basel). 10 (2018).


Pourjavadi, A., Seidi, F., Salimi, H. & Soleyman, R. Grafted CMC/silica gel superabsorbent composite: Synthesis and investigation of swelling behavior in various media. J. Appl. Polym. Sci.


108, 3281–3290 (2008).


Article  CAS  Google Scholar 


Ramazani-Harandi, M. J., Zohuriaan-Mehr, M. J., Yousefi, A. A., Ershad-Langroudi, A. & Kabiri, K. Effects of structural variables on AUL and rheological behavior of SAP gels. J. Appl. Polym.


Sci. 113, 3676–3686 (2009).


Article  CAS  Google Scholar 


Ramazani-Harandi, M. J., Zohuriaan-Mehr, M. J., Yousefi, A. A., Ershad-Langroudi, A. & Kabiri, K. Rheological determination of the swollen gel strength of superabsorbent polymer hydrogels.


Polym. Test. 25, 470–474 (2006).


Article  CAS  Google Scholar 


Davis, C. R., Kelly, S. L. & Erk, K. A. Comparing laser diffraction and optical microscopy for characterizing superabsorbent polymer particle morphology, size, and swelling capacity. J.


Appl. Polym. Sci. 135, 46055 (2018).


Article  CAS  Google Scholar 


Agaba, H. et al. Effects of Hydrogel Amendment to Different Soils on Plant Available Water and Survival of Trees under Drought Conditions. CLEAN - Soil, Air. Water 38, 328–335 (2010).


ADS  CAS  Google Scholar 


Leciejewski, P. The effect of hydrogel additives on the water retention curve of sandy soil from forest nursery in Julinek. J. Water L. Dev. 13a, 239–247 (2009).


Google Scholar 


Yu, J. et al. Superabsorbent Polymer Properties and Concentration Effects on Water Retention under Drying Conditions. Soil Sci. Soc. Am. J. 81, 889 (2017).


Article  ADS  CAS  Google Scholar 


Akhter, J. et al. Effects of hydrogel amendment on water storage of sandy loam and loam soils and seedling growth of barley, wheat and chickpea. Plant, Soil Environ. 50, 463–469 (2011).


Article  Google Scholar 


Salimi, H., Pourjavadi, A., Seidi, F., Jahromi, P. E. & Soleyman, R. New smart carrageenan-based superabsorbent hydrogel hybrid: Investigation of swelling rate and environmental


responsiveness. J. Appl. Polym. Sci. 117, n/a–n/a (2010).


Article  CAS  Google Scholar 


Lejcuś, K. et al. Optimisation of Operational Parameters for Nonwoven Sheaths of Water Absorbing Geocomposites in Unsaturated Soil Conditions. Fibres Text. East. Eur. 24, 110–116 (2016).


Article  Google Scholar 


Essawy, H. A., Ghazy, M. B. M., El-Hai, F. A. & Mohamed, M. F. Superabsorbent hydrogels via graft polymerization of acrylic acid from chitosan-cellulose hybrid and their potential in


controlled release of soil nutrients. Int. J. Biol. Macromol. 89, 144–151 (2016).


Article  CAS  PubMed  Google Scholar 


Lawal, O. S. et al. Hydrogels based on carboxymethyl cassava starch cross-linked with di- or polyfunctional carboxylic acids: Synthesis, water absorbent behavior and rheological


characterizations. Eur. Polym. J. 45, 3399–3408 (2009).


Article  CAS  Google Scholar 


Download references


Author informationAuthors and Affiliations Wrocław University of Environmental and Life Sciences, Institute of Environmental Engineering, Wrocław, 50-363, Poland


Jakub Misiewicz, Krzysztof Lejcuś & Daria Marczak


Wrocław University of Life and Environmental Sciences, Institute of Building Engineering, Wrocław, 50-363, Poland


Jolanta Dąbrowska


AuthorsJakub MisiewiczView author publications You can also search for this author inPubMed Google Scholar


Krzysztof LejcuśView author publications You can also search for this author inPubMed Google Scholar


Jolanta DąbrowskaView author publications You can also search for this author inPubMed Google Scholar


Daria MarczakView author publications You can also search for this author inPubMed Google Scholar

Contributions


Jakub Misiewicz prepared methodology and conducted laboratory tests, prepared data analysis, and wrote the main manuscript text. Krzyszt of Lejcuś prepared research concept, wrote abstract


and conclusions section. Jolanta Dąbrowska and Jakub Misiewicz prepared statistical analysis. Daria Marczak prepared Figures 1–4 and Tables 1–4. We ensure that all co-authors agree to submit


them to the journal.


Corresponding author Correspondence to Krzysztof Lejcuś.

Ethics declarations Competing interests


The authors declare no competing interests.

Additional information


Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions


Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or


format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or


other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in


the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the


copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.


Reprints and permissions


About this articleCite this article Misiewicz, J., Lejcuś, K., Dąbrowska, J. et al. The Characteristics of Absorbency Under Load (AUL) for Superabsorbent and Soil Mixtures. Sci Rep 9, 18098


(2019). https://doi.org/10.1038/s41598-019-54744-4


Download citation


Received: 11 June 2019


Accepted: 19 November 2019


Published: 02 December 2019


DOI: https://doi.org/10.1038/s41598-019-54744-4


Share this article Anyone you share the following link with will be able to read this content:


Get shareable link Sorry, a shareable link is not currently available for this article.


Copy to clipboard Provided by the Springer Nature SharedIt content-sharing initiative


This article is cited by Investigating the Impact of Superabsorbent Polymer on Compaction and Shear Strength of Clayey Soil Elahe JafariJie HuangFei Wang International Journal of


Geosynthetics and Ground Engineering (2025)


Hydrogels in Agriculture: Prospects and Challenges Prabhpreet KaurRuchi AgrawalHimadri B. Bohidar Journal of Polymers and the Environment (2023)


Recycling Natural Fibre to Superabsorbent Hydrogel Composite for Conservation of Irrigation Water in Semi-arid Regions Abhisekh SahaChandra Bhanu GuptSreedeep Sekharan Waste and Biomass


Valorization (2021)


Transformation of non-water sorbing fly ash to a water sorbing material for drought management Abhisekh SahaSreedeep SekharanLingaraj Sahoo Scientific Reports (2020)