Dual-energy micro-ct for quantifying the time-course and staining characteristics of ex-vivo animal organs treated with iodine- and gadolinium-based contrast agents
- Select a language for the TTS:
- UK English Female
- UK English Male
- US English Female
- US English Male
- Australian Female
- Australian Male
- Language selected: (auto detect) - EN
Play all audios:
ABSTRACT Chemical staining of soft-tissues can be used as a strategy to increase their low inherent contrast in X-ray absorption micro-computed tomography (micro-CT), allowing to obtain fast
three-dimensional structural information of animal organs. Though some staining agents are commonly used in this context, little is known about the staining agents’ ability to stain
specific types of tissues; the times necessary to provide a sufficient contrast; and the effect of staining solution in distorting the tissue. Here we contribute to studies of animal organs
(mouse heart and lungs) using staining combined with dual-energy micro-CT (DECT). DECT was used in order to obtain an additional quantitative measure for the amount of staining agents within
the sample in 3D maps. Our results show that the two staining solutions used in this work diffuse differently in the tissues studied, the staining times of some tens of minutes already
produce high-quality micro-CT images and, at the concentrations applied in this work, the staining solutions tested do not cause relevant tissue distortions. While one staining solution
provides images of the general morphology of the organs, the other reveals organs’ features in the order of a hundred micrometers. SIMILAR CONTENT BEING VIEWED BY OTHERS DUAL-RADIONUCLIDE IN
VIVO IMAGING OF MICRO-METASTASIS AND LYMPH TRACT WITH SUBMILLIMETRE RESOLUTION Article Open access 09 November 2023 CORRELATIVE SINGLE-CELL HARD X-RAY COMPUTED TOMOGRAPHY AND X-RAY
FLUORESCENCE IMAGING Article Open access 07 March 2024 FEASIBILITY STUDY OF PORTABLE MULTI-ENERGY COMPUTED TOMOGRAPHY WITH PHOTON-COUNTING DETECTOR FOR PRECLINICAL AND CLINICAL APPLICATIONS
Article Open access 23 November 2021 INTRODUCTION Chemical staining of animal tissues is an appropriate strategy to increase the low inherent contrast of soft-tissues in X-ray absorption
micro-computed tomography (micro-CT)1,2,3. With this strategy, three-dimensional (3D) structural information on mammals2,4,5,6 and other animals3,7,8,9 in their healthy or diseased
states10,11 are easily accessed. Since the first works published about combining staining with micro-CT10,12,13, this strategy has supported several functional and morphological
studies5,12,14,15. Among the chemical agents explored for micro-CT, the list of those most often used includes a few medical contrast media applied in the clinic in Magnetic Resonance
Imaging (MRI) and X-ray Computed Tomography (CT)10,16,17; and iodine (I2), either simply diluted in alcohol (ethanol or methanol) or in aqueous solution with potassium iodide (KI)9,12,13,18.
Although those staining agents are widely used for micro-CT, still little is known about the staining times necessary to provide a satisfactory increase of contrast; the effect of the
staining solution in creating tissue distortions and changes to the overall size of the sample; and the differences in the staining agents’ ability to stain specific types of tissues.
Staining times varying from a few hours to some weeks are described in the literature14,15, sometimes making the protocols time consuming, thus, not applicable in laboratory routines.
Although sample contraction due to the use of alcohol-based staining agents has already been described9,18, an evaluation of the benefits in contrast enhancement in the context of tissue
shrinkage and distortions is still incomplete, as well as a comparison of the ability of a staining solution to stain one or other type of tissue. The architecture of _ex-vivo_ mouse heart
and lungs has already been well described with staining combined with micro-CT2,4,5,19,20,21,22. Thus, rather than providing a morphological description of these organs, here we contribute
to the studies of soft-tissues’ staining combined with micro-CT, by providing new quantitative information about the diffusion of staining solutions due to staining time, tissue type and
staining solution type. For that, we stained _ex-vivo_ mouse heart and lungs controlling the time and using two well known contrast-enhancing solutions: one based on iodine (I2 in ethanol,
known as I2E) and the other on gadolinium (Gadovist). We imaged the samples with a dual-energy micro-CT (DECT) technique, exploring an easy-to-use image acquisition protocol based on the
knowledge of the X-ray emission spectrum and the sample components. When compared to regular micro-CT, DECT has the great advantage of providing a quantitative description of the staining
agent content within the organs. Thus, our measurements allow a segmentation of the staining agents within the tissues and we could then create 3D maps of the distribution of the contrast
agents within the samples. Our results describe for the first time the major differences in contrast and in sample size due to staining time, tissue type and contrast agent. Furthermore, our
measurements reveal that much shorter staining times than those usually described in the literature are enough to provide high-quality micro-CT images with high-resolution for these organs.
RESULTS To study the effect of the staining time and the staining agent type on the contrast in micro-CT images, we performed sequential staining procedures on mice heart and attached lungs
controlling the staining times and using either I2E or Gadovist as contrast-enhancing agent. We consecutively X-ray imaged the samples after each staining procedure, as illustrated in Fig.
1 for I2E staining. Imaging was performed with two different X-ray energy spectra, at a low- and a high-energy. SINGLE-ENERGY SPECTRA IMAGING A comparison between tomograms of non-stained
and I2E-stained heart imaged at low-energy (40 kVp) shows that the non-stained sample delivers poor contrast among tissues in the organ and, thus, all sample features are lost in the low
signal-to-noise ratio (Fig. 2A and a2). A better contrast is obtained in the tomogram of the heart stained for 30 min with I2E, with the borders of the organ well delineated (Fig. 2B).
Indeed, the tomograms of the heart imaged in the same experimental conditions show an increase in contrast with the increasing I2E-staining times (Fig. 2A–F). This effect is clearly seen in
the histograms, and after each staining round, the signal representing the gray values distribution of the sample continuously shifts away from the background signal (black dashed line in
Fig. 2 and S1 a1-f1). The details revealed with the staining time include the orientation of the muscular fibers in the intraventricular septum (IVS) and the inner and outer walls of the
heart, which can be identified after only 60 min of staining (Fig. 2C). Though after 90 min the saturation of the staining agent in the tissue composing the heart walls is reached (Fig. 2
d2-f2, light-gray areas), longer staining times still cause an increase in the relative intensity of the signal related to the IVS (Fig. 2, a2–f2, dark gray area). Similar observations are
also made for the lung tissue after each staining round with I2E, as a general increase in contrast is observed in the lungs, with the airways better delineated after each staining round
(Supplementary Fig. S1). After 180 min of staining, I2E highlights structures of less than 100 μm in the lungs. Specifically in the esophagus, a more intense increase in contrast is observed
compared with structures in the lungs (Supplementary Fig. S1, white arrow). We performed a similar study with heart and attached lungs consecutively stained with Gadovist and imaged at a
low energy (70 kVp). As observed for I2E staining, Gadovist-stained samples also show an improvement in contrast with increasing staining times, as seen in the tomograms, in the histograms
and in the line plot values of the stained heart and lungs (Fig. 3 and S2). However, a general increase in contrast of the entire sample is seen after each Gadovist staining round, thus,
almost no detail of the tissues’ morphology is revealed, such as the fibrous muscular tissue of the intraventricular septum and the heart walls or micrometric structures in the lungs. After
the staining procedure, an amount of Gadovist solution remains in the heart ventricles (Fig. 3, black arrows). This same effect is observed in some lungs’ airways (Supplementary Fig. S2,
black arrows), and the airways surface are then seen in a darker tone than the lung tissue and the airways. The excellent contrast generated by longer staining times allowed us to better
reconstruct the parts of the heart and lungs stained with I2E (Fig. 4A–D) and Gadovist (Fig. 5A–D). DUAL-ENERGY SPECTRA IMAGING Though the single-energy spectra imaging allows to observe the
increase in contrast due to staining time, dual-energy micro-CT enables a deeper insight into the distribution of the staining media with a high spatial resolution. Dual-energy micro-CT
quantifies the local concentration of the staining agent and we then used this technique to better identify the accumulation of the contrast agent on specific parts of the organs analysed.
We processed the data obtained with two different X-ray energy spectra using an image-based material decomposition method for dual-energy X-ray computed tomography (Supplementary Fig. S3)23.
This technique provides a quantification of the staining agent content regardless of the tissue density. Thus, in the maps of the distribution of iodine or gadolinium in the samples, we see
the areas where the contrast-enhancing solutions tend to accumulate (Figs 4E–L and 5E–L, with the red-coloured areas containing the higher amounts, respectively, of iodine and gadolinium).
The concentration gradient of the contrast-enhancing element is clearly visualised from the outside to the inside in the sliced volumes of I2E-stained samples (Fig. 4F–H). According to the
3D staining map of iodine, the contrast is equally increased in the entire sample after the first staining round (Fig. 4F and J). After 90 min of staining, there is a differentiation of the
lung tissue and the heart tissue, with the latter accumulating a higher amount of iodine (Fig. 4G and K). A 150-min staining time result in a more pronounced staining differentiation between
heart and lung tissues, and the heart walls (Fig. 4H and L). The gadolinium maps show that Gadovist accumulates mostly in the lungs than in other tissues after 60 min of staining (Fig. 5F
and J). With longer staining times, this effect is pronounced and, after 180 min of staining, the profile of the lungs lobes is well delineated, the heart walls are depicted with the blood
vessels highlighted on its surface (Fig. 5H and L). Due to longer staining times, along with the gain in contrast that can be quantified by the increasing range and values of attenuation
coefficients (Fig. 6A and B), changes in the total samples volumes are also observed after the sequential staining procedures (Fig. 6C and D). A shrinkage of approximately 20% occurs after
the first I2E-staining round, as expected after changing the organ from fixative aqueous solution to the ethanolic I2E solution. The sample size remains virtually unchanged after each of the
further staining sessions (Fig. 6C). The sample size changes by less than 10% with the sequential Gadovist-staining procedures (Fig. 6D). DISCUSSION Our present study has focused on the
time necessary for two commonly used staining solutions (I2E and Gadovist) to increase the contrast in micro-CT and on the differences observed in the accumulation of these contrast agents
in the heart and lungs of _ex-vivo_ mouse. We used an imaging protocol with two different X-ray energy spectra sequentially acquired. The single low X-ray energy spectrum tomograms and
histograms of the samples stained with I2E (Fig. 2 and S1) and Gadovist (Fig. 3 and S2) show the uptake of these solutions in the heart and lungs, and the increase in contrast that is
related to the staining agent and the staining time. Indeed, after each staining round, the gradual shift of the soft-tissue signal in the histograms is consistent with the wider range of
intensity values of the samples stained for longer periods of time. Though conventional micro-CT imaging (single-energy spectra) shows the increase in contrast due to staining time, the
combined processing of the two datasets obtained with two different X-ray energy spectra result in a three-dimensional map of the staining agent content per voxel. This 3D map cannot be
achieved with conventional micro-CT imaging because X-ray attenuation of the tissue cannot be eliminated even for a well-calibrated system. Dual-energy scans, on the other hand, allow
quantitative calibration for the known absorbing materials (iodine and gadolinium) present in the staining agents used. Therefore here, to obtain a quantified distribution of contrast agent
in the samples, we processed the two different X-ray energy spectra using an image-based material decomposition method for dual energy X-ray computed tomography (Supplementary Fig. S3)24.
The main requirement for material decomposition on sequentially acquired computed tomographies is an adequate distinction of the X-ray energy spectra used with respect to the attenuating
material for a broad-band X-ray source. This means that, either the spectra must differ sufficiently by being shaped with filters and different peak energies (Supplementary Figs S4 and S5),
or that the attenuation coefficient of the main absorbing material varies significantly over the specified energy range. This is the case for the regime around an X-ray absorption edge. A
combination of both was used for our choice of imaging parameters following to the obtained spectra. On one hand, this dual-energy imaging protocol helps discriminating two known materials
in the measured sample as it allows differentiation of, for example, iodine or gadolinium from soft-tissue, independent of the density of the staining element and the total X-ray
attenuation. On the other hand, it allows quantification of changes in concentration or density of a specific material over the entire sample with high sensitivity. Image-based material
segmentation methods suffer from image artifacts such as beam hardening, but the reliability of these techniques can be improved using the information obtained with material phantom
measurements (Supplementary Figs S6 and S7). The material-selective volumes obtained by dual-energy imaging for iodine (Fig. 4) or gadolinium (Fig. 5) display the concentrations of these
elements and allows quantification of the diffusion process, particularly in the three-dimensional view. The numbers on the colour bars in Figs 4 and 5 refer to the fraction of the iodine or
gadolinium solution used for calibration of the setup. These solutions were identical to the media used for the staining (0.5% I2 w/v, named I2E; and pure Gadovist). In consequence, a
comparison between the material-selective volumes for the different solutions shows that I2E first accumulates in the heart (up to approximately 1.3 times the staining solution concentration
at longer staining times) and gives a strong contrast also for small sample features in the organ, whilst Gadovist has higher concentrations in the lung tissue (Fig. 5E–H and I–L) and does
not depict the small details neither in the heart nor in the lung tissues. After 90 min, structural details are seen in the I2E stained heart, but not in the lungs. In contrast, the heart
stained with Gadovist requires longer staining times than the lungs require to appear well depicted in the images. I2E increases the contrast of the heart walls more than the blood vessels
(Fig. 5L) and Gadovist accumulates more in the blood vessels and less in the heart walls, thus, thus highlighting the heart blood vessels. Another difference consists in the areas where the
staining solution accumulates in the lungs and adjacent tissues: I2E accumulates in the airways walls of the lungs (bronchial tree) and in the esophagus (Supplementary Fig. S1, arrow), while
the Gadovist diffuse and accumulate in the entire organ, but not much in the esophagus and in the airways walls, that therefore appear in a shade (Supplementary Fig. S2). The general
differences observed between I2E and Gadovist staining are related to their ability to stain the heart, the esophagus and lungs’ airways. Our results agree with published data, which show
that among other types of soft-tissues, the iodine-stained muscular tissue shows the highest grayscale values when compared to other types of tissues9. Indeed, according to the literature,
muscle tissues (like those composing the heart) and epithelial tissues (lining the esophagus and parts of the bronchial tree) are well stained by iodine-containing solutions (both water- and
ethanol-based) possibly due to local anisotropy in tissue diffusivity9. For Gadovist staining, our results suggest that the diffusibility of Gadovist into the lungs’ airways plays a more
critical role than the local anisotropy of muscular tissue of the heart. The difference in the staining process between I2E and Gadovist is also illustrated by the different profile of the
curves showing how the values of attenuation coefficients change with the staining time (Fig. 6A and B). Our results show that I2E staining caused a more pronounced change in size than
Gadovist staining (Fig. 6C and D). Sample shrinkage is already described in the literature for I2E9,18, due to the presence of ethanol used as solvent, which is known to remove water from
tissues9,25. Also, the I2E staining procedure used here involved a previous step of dehydration of the organs in ethanol, that is known to increase cells membrane permeation, helping iodine
diffusion into the organs2. Thus, the overall size differences observed between I2E- and Gadovist-stained samples are more likely to be due to the dehydration effect of the ethanol used in
the I2E staining solution. Still, the dehydration caused by ethanol does not seem to cause distortions in the heart and lung tissue, at least in the sample features that are observable in
the images presented here. In contrast, the Gadovist is a water-based solution26, that causes virtually no sample shrinkage. The variations in volume observed for Gadovist, and for I2E after
30 min of staining, could be due to small errors in the automated size measurements or due to small changes in the position of the sample in the plastic tube during the staining steps.
Besides observing the staining maps, another way of interpreting dual-energy CT results is the use of two-dimensional correlation histograms, which represent the number of voxels with a
certain combination of effective polychromatic attenuation coefficients measured for low- and high-energy (Supplementary Fig. S8 for I2E-stained sample and Supplementary Fig. S9 for
Gadovist-stained sample)27. The two-dimensional correlation histograms results show that, whilst only a small range of attenuation coefficients represent soft-tissue (organ), plastic (sample
container) and air (negative values correspond to scattering by the sample), the diversity of attenuation coefficients increases rapidly due to the staining. With increasing staining times,
the number of voxels with a large attenuation coefficient corresponding to a high amount of I2E also increases, which refers to iodine accumulation in the tissue (Supplementary Fig. S8). In
the correlation histograms for staining with Gadovist, the amount of the staining solution in the lung tissue is clearly differentiated from the amount in the heart tissue (Supplementary
Fig. S9). Indeed, over time the lung tissue becomes saturated and the Gadovist concentration inside the heart approaches saturation at the longest staining time used in this work. In
conclusion, our easy-to-use dual-energy X-ray micro-CT acquisition protocol and data analysis allow the quantification and the segmentation of staining agents within soft-tissues samples.
Our results describe the major differences in contrast due to the staining time, the staining agent used and the organ studied. Supported by the 3D mapping of the contrast agent accumulation
in the organs, our results show a clear improvement in contrast after every staining round with the two staining solutions tested, which are both commonly employed in micro-CT. Moreover,
they show that the staining solutions used here diffuse differently in heart and lung tissues, and the saturation of some tissues is virtually reached in less than 3 h of staining procedure.
Thus, we show that much shorter staining times than those described in the literature (ranging from hours to weeks) are enough to generate contrast to provide high-quality micro-CT images
with high-resolution. When comparing the two staining solutions used, Gadovist is a good contrast agent to reveal the general morphology of the organs studied, while I2E provides more
detailed images with features in the order of a hundred micrometers, though heart’s blood vessels are well depicted by both staining solutions. Also, the combination of two effects, the
local anisotropy in tissue diffusivity and the higher permeability of tissues immersed in ethanol solutions, are in agreement with I2E being capable of staining the heart, the esophagus and
the bronchial tree faster than it stains the lungs tissues, while the opposite is observed for Gadovist. METHODS SAMPLES PREPARATION Organ removal was approved from an internal animal
protection committee of the preclinical centre (ZPF) of Klinikum rechts der Isar, Munich, Germany (internal reference number 4-005-09). Two 6 months old female C57Bl/6 mice (Charles River
Laboratories, Europe) were sacrificed in accordance with relevant guidelines and regulations, and lungs and hearts were excised and fixed in 1% formaldehyde/ 2,5% glutaraldehyde in 1x PBS.
All staining and imaging procedures were performed in the same container, and care was taken to prevent the samples moving in between staining procedures to avoid alignment issues during
image processing. Only freshly prepared staining solutions were used in all staining steps. For micro-CT imaging of the staining time 0, the sample was removed from the fixative solution and
inserted in a plastic tube with a small volume of fixative solution in the bottom of the tube, not touching the sample. Imaging was performed with the tube closed to prevent the sample from
drying. Immediately afterwards, the heart and attached lungs were dehydrated in a graded series of ethanol solutions (50, 70, 80, 90, 96% and absolute ethanol for 1 h each), then they were
left in the iodine staining solution (0.5% w/v I2 in absolute ethanol, named I2E). After 30 min-staining, the staining solution was removed from the container, the organs were washed 3 times
in pure ethanol and the sample was imaged in a closed plastic tube containing enough ethanol to prevent the sample from drying, but without touching it. This 30 min staining procedure
followed by micro-CT imaging was repeated consecutively 5 times, thus, the organs were imaged for staining times equal to 30, 60, 90, 120 and 150 min. For the heart and lungs stained with
Gadovist™ (Bayer Healthcare - solution for intravenous injection containing 604.72 mg mL−1 of Gadobutrol (1.0 mmol mL−1 solution of
10-(2,3-dihydroxy-1-hydroxymethylpropyl)-1,4,7,10-tetraazacyclododecane-1,4,7-triacetic acid)), a similar procedure of staining followed by micro-CT imaging was performed. Though, since both
Gadovist and fixative solutions are both aqueous solutions, the dehydration step necessary for I2E staining was not performed here. Heart and lungs were removed from the fixative solution
and first imaged with micro-CT, corresponding to the staining time 0. Then, they were washed 3 times in deionised water and stained for 60 min with pure Gadovist. This 60 min staining
procedure followed by micro-CT imaging was repeated consecutively 2 more times, thus, the organs were imaged for staining times equal to 60, 120 and 180 min. DATA ACQUISITION Due to the
possibility to maintain a sub-micrometer-resolution even for large samples, a VersaXRM-500 3D X-ray microscope from Zeiss was used to acquire the X-ray computed tomography measurements. All
measurement parameters were chosen in a way to reach an appropriate signal-to-noise ratio for a sufficiently short scan time, to avoid sample movement during the scan. A dual energy
technique was used to attain an iodine or gadolinium-specific image, which particularises the element distribution over the heart and lungs samples. The dual energy technique relies on the
energy dependence of the X-ray attenuation for different materials (Supplementary Figs S6B and S7B). The samples were imaged with a low energy spectrum (40.2 kVp for the iodine-stained
sample and 60.2 kVp for the gadolinium-stained sample) and immediately after with a high energy spectrum (70.1 kVp for the iodine-stained sample and 140.0 kVp for the gadolinium-stained
sample), using the parameters in Table S1. Additionally, filter materials supported a sufficient separation of the X-ray emission spectra observed for every measurement (Supplementary Figs
S6A and S7A). For the calibration of the system, phantoms consisting of a rod of PMMA as a soft-tissue equivalent material and an Eppendorf tube filled with the staining agent 0.5% I2E or
Gadovist™ were used (Supplementary Figs S4A,B and S5A,B). They were measured with the same scanning parameters as for the main measurements (Supplementary Table S1) and the material
decomposition algorithm was tested on them (Supplementary Figs S4C,D and S5C,D). The attenuation coefficients of the basis materials were calculated as the mean values of the reconstructed
PMMA rod and the content of the Eppendorf tube (Supplementary Table S2). DIGITAL IMAGE PROCESSING AND DUAL-ENERGY DECOMPOSITION The image processing steps are presented in the flowchart in
Supplementary Fig. S3 and described in the following text. To achieve high accuracy in image registration, it was necessary to align the dual-energy datasets with each other before
reconstruction and to perform an additional post-reconstruction image alignment of the volumes. These steps consider a shift in both translation and rotation. Furthermore, median filtering
was used for noise reduction. The sample segmentation was done by drawing region of interests manually and performing linear interpolation in between. The dual-energy decomposition makes use
of two CT scans consecutively acquired at two different energy spectra (Supplementary Figs S8A and S9A) to isolate the contribution of a specific material. Especially for the
non-simultaneous scanning procedure, which does not require a designated dual-energy CT setup, it is recommended to perform the decomposition post-reconstruction as this simplifies the
necessary image registration significantly. Even though this method does not prevent image artifacts such as beam hardening, it provides a satisfying quantitative description of the material
contents, which gives an insight into the distribution of a contrast medium and enhances the understanding of the molecular behaviour. For material decomposition we used a linear
optimisation approach with non-negative constraints23. This solves voxel-wise systems of equations describing a composition of two materials given by: $$\begin{array}{c}{\mu
}_{{\rm{HE}}}({\rm{x}},{\rm{y}},{\rm{z}})={\mu }_{\mathrm{stain},\mathrm{HE}}\ast {{\rm{F}}}_{{\rm{stain}}}({\rm{x}},{\rm{y}},{\rm{z}})+{\mu }_{\mathrm{PMMA},\mathrm{HE}}\ast
{{\rm{F}}}_{{\rm{PMMA}}}({\rm{x}},{\rm{y}},{\rm{z}}),\\ {{\rm{\mu }}}_{{\rm{LE}}}({\rm{x}},{\rm{y}},{\rm{z}})={\mu }_{{\rm{stain}},{\rm{LE}}}\ast {{\rm{F}}}_{{\rm{stain}}}(x,y,z)+{\mu
}_{\mathrm{PMMA},\mathrm{LE}}\ast {{\rm{F}}}_{{\rm{PMMA}}}({\rm{x}},{\rm{y}},{\rm{z}}).\end{array}$$ The polychromatic attenuation coefficients µHE (high energy) and µLE (low energy) are
given by the flat field corrected reconstructed volumes. The values µstain and µPMMA can be obtained from calibration measurements as explained above. The resulting material-specific
F(x,y,z) gives the fraction of each calibration material for every voxel. Using air as a third material for the decomposition leads to an improvement of the results. The attenuation
coefficients are given as the mean value of phantom-free regions in the reconstructed calibration measurements. The systems of equations change to: $$\begin{array}{c}{\mu
}_{{\rm{HE}}}({\rm{x}},{\rm{y}},{\rm{z}})={\mu }_{\mathrm{stain},\mathrm{HE}}\ast {{\rm{F}}}_{{\rm{stain}}}({\rm{x}},{\rm{y}},{\rm{z}})+{\mu }_{\mathrm{PMMA},\mathrm{HE}}\ast
{{\rm{F}}}_{{\rm{PMMA}}}({\rm{x}},{\rm{y}},{\rm{z}}){+\mu }_{\mathrm{air},\mathrm{HE}}\ast {{\rm{F}}}_{{\rm{air}}}({\rm{x}},{\rm{y}},{\rm{z}}),\\ {\mu
}_{{\rm{LE}}}({\rm{x}},{\rm{y}},{\rm{z}}){=\mu }_{\mathrm{stain},\mathrm{LE}}\ast {{\rm{F}}}_{{\rm{stain}}}({\rm{x}},{\rm{y}},{\rm{z}}){+\mu }_{\mathrm{PMMA},\mathrm{LE}}\ast
{{\rm{F}}}_{{\rm{PMMA}}}({\rm{x}},{\rm{y}},{\rm{z}}){+\mu }_{\mathrm{air},\mathrm{LE}}\ast {{\rm{F}}}_{{\rm{air}}}({\rm{x}},{\rm{y}},{\rm{z}}),\\ \quad \quad \quad \quad
{1={\rm{F}}}_{{\rm{stain}}}({\rm{x}},{\rm{y}},{\rm{z}}){+{\rm{F}}}_{{\rm{PMMA}}}({\rm{x}},{\rm{y}},{\rm{z}}){+{\rm{F}}}_{{\rm{air}}}({\rm{x}},{\rm{y}},{\rm{z}}){\rm{.}}\end{array}$$ The
validation of the algorithm is shown by the decomposition of the phantoms used for calibration (Supplementary Figs S4 and S5). SAMPLE VOLUME EVALUATION The volume of the samples was computed
from the low energy CT data. The sample container was removed manually by a drawing tool in FEI Avizo Fire 8.1 and voxels consisting of air were set to zero by simple thresholding. Holes
and chambers inside the sample were excluded from this step and they also contribute to the sample total volume. The whole number of voxels containing values larger than zero were counted
automatically and multiplied with (pixel size)3 to obtain the final volume (see Table). Though the size measurement approach might not give an absolute size value, it is an accessible method
to compare sample volumes changes. AVAILABILITY OF DATA AND MATERIAL The datasets used and/or analysed during the current study are available from the corresponding author on reasonable
request. REFERENCES * Gignac, P. M. & Kley, N. J. Iodine-enhanced micro-CT imaging: methodological refinements for the study of the soft-tissue anatomy of post-embryonic vertebrates. _J
Exp Zool B Mol Dev Evol_ 322, 166–176, https://doi.org/10.1002/jez.b.22561 (2014). Article PubMed Google Scholar * de Souza e Silva, J. M. _et al_. Three-dimensional non-destructive
soft-tissue visualization with X-ray staining micro-tomography. _Sci Rep_ 5, 14088, https://doi.org/10.1038/srep14088 (2015). Article ADS Google Scholar * Smith, D. B. _et al_. Exploring
miniature insect brains using micro-CT scanning techniques. _Sci Rep-Uk_ 6, https://doi.org/10.1038/srep21768 (2016). * Stephenson, R. S. _et al_. Contrast enhanced micro-computed tomography
resolves the 3-dimensional morphology of the cardiac conduction system in mammalian hearts. _PLoS One_ 7, e35299, https://doi.org/10.1371/journal.pone.0035299 (2012). Article ADS CAS
PubMed PubMed Central Google Scholar * Aslanidi, O. V. _et al_. Application of micro-computed tomography with iodine staining to cardiac imaging, segmentation, and computational model
development. _IEEE Trans Med Imaging_ 32, 8–17, https://doi.org/10.1109/TMI.2012.2209183 (2013). Article PubMed Google Scholar * Balint, R., Lowe, T. & Shearer, T. Optimal Contrast
Agent Staining of Ligaments and Tendons for X-Ray Computed Tomography. _Plos On_e 11, https://doi.org/10.1371/journal.pone.0153552 (2016). * Holliday, C. M., Tsai, H. P., Skiljan, R. J.
& George, I. D. & Pathan, S. A 3D interactive model and atlas of the jaw musculature of Alligator mississippiensis. _PLoS One_ 8, e62806, https://doi.org/10.1371/journal.pone.0062806
(2013). Article ADS CAS PubMed PubMed Central Google Scholar * Gignac, P. M. _et al_. Diffusible iodine-based contrast-enhanced computed tomography (diceCT): an emerging tool for
rapid, high-resolution, 3-D imaging of metazoan soft tissues. _J Anat_ 228, 889–909, https://doi.org/10.1111/joa.12449 (2016). Article CAS PubMed PubMed Central Google Scholar * Li, Z.,
Ketcham, R. A., Yan, F., Maisano, J. A. & Clarke, J. A. Comparison and Evaluation of the Effectiveness of Two Approaches of Diffusible Iodine-Based Contrast-Enhanced Computed Tomography
(diceCT) for Avian Cephalic Material. _J Exp Zool B Mol Dev Evol_ 326, 352–362, https://doi.org/10.1002/jez.b.22692 (2016). Article CAS PubMed Google Scholar * de Crespigny, A. _et al_.
3D micro-CT imaging of the Postmortem Brain. _Journal of neuroscience methods_ 171, 207–213, https://doi.org/10.1016/j.jneumeth.2008.03.006 (2008). Article PubMed PubMed Central Google
Scholar * Ashton, J. R. _et al_. Dual-Energy Micro-CT Functional Imaging of Primary Lung Cancer in Mice Using Gold and Iodine Nanoparticle Contrast Agents: A Validation Study. _Plos One_ 9,
https://doi.org/10.1371/journal.pone.0088129 (2014). * Metscher, B. D. MicroCT for comparative morphology: simple staining methods allow high-contrast 3D imaging of diverse non-mineralized
animal tissues. _BMC Physiol_ 9, 11, https://doi.org/10.1186/1472-6793-9-11 (2009). Article PubMed PubMed Central Google Scholar * Metscher, B. D. MicroCT for developmental biology: a
versatile tool for high-contrast 3D imaging at histological resolutions. _Dev Dyn_ 238, 632–640, https://doi.org/10.1002/dvdy.21857 (2009). Article PubMed Google Scholar * Faulwetter, S.,
Vasileiadou, A., Kouratoras, M., Dailianis, T. & Arvanitidis, C. Micro-computed tomography: Introducing new dimensions to taxonomy. _Zookeys_, 1–45,
https://doi.org/10.3897/zookeys.263.4261 (2013). * Cox, P. G. & Faulkes, C. G. Digital dissection of the masticatory muscles of the naked mole-rat, Heterocephalus glaber (Mammalia,
Rodentia). _Peerj_ 2, https://doi.org/10.7717/peerj.448 (2014). * Saito, S. & Murase, K. _Ex vivo_ imaging of mouse brain using micro-CT with non-ionic iodinated contrast agent: a
comparison with myelin staining. _Br J Radiol_ 85, e973–978, https://doi.org/10.1259/bjr/13040401 (2012). Article CAS PubMed PubMed Central Google Scholar * Lusic, H. & Grinstaff,
M. W. X-ray-computed tomography contrast agents. _Chem Rev_ 113, 1641–1666, https://doi.org/10.1021/cr200358s (2013). Article CAS PubMed Google Scholar * Buytaert, J., Goyens, J., De
Greef, D., Aerts, P. & Dirckx, J. Volume shrinkage of bone, brain and muscle tissue in sample preparation for micro-CT and light sheet fluorescence microscopy (LSFM). _Microsc Microanal_
20, 1208–1217, https://doi.org/10.1017/S1431927614001329 (2014). Article ADS CAS PubMed Google Scholar * Ritman, E. L. Micro-computed tomography of the lungs and pulmonary-vascular
system. _Proc Am Thorac Soc_ 2, 477–480, 501, https://doi.org/10.1513/pats.200508-080DS (2005). Article PubMed PubMed Central Google Scholar * Li, M. _et al_. Growth pattern analysis of
murine lung neoplasms by advanced semi-automated quantification of micro-CT images. _PLoS One_ 8, e83806, https://doi.org/10.1371/journal.pone.0083806 (2013). Article ADS PubMed PubMed
Central Google Scholar * Descamps, E. S. _et al_. tissue discrimination with contrast agents using micro-CT scanning. _Belg J Zool_ 144 (2014). * de, Se. S. J. M. _et al_.
Three-dimensional non-destructive soft-tissue visualization with X-ray staining micro-tomography. _Sci Rep_ 5, 14088, https://doi.org/10.1038/srep14088 (2015). Article Google Scholar *
Badea, C. T. _et al_. Dual-energy micro-CT of the rodent lung. _Am J Physiol Lung Cell Mol Physiol_ 302, L1088–1097, https://doi.org/10.1152/ajplung.00359.2011 (2012). Article CAS PubMed
PubMed Central Google Scholar * Handschuh, S., Beisser, C. J., Ruthensteiner, B. & Metscher, B. D. Microscopic dual-energy CT (microDECT): a flexible tool for multichannel _ex vivo_ 3D
imaging of biological specimens. _J Microsc_ 267, 3–26, https://doi.org/10.1111/jmi.12543 (2017). Article CAS PubMed Google Scholar * Bancroft, J. D. & Gamble, M. Theory and
practice of histological techniques. 5th edn, (Churchill Livingstone, 2002). * Inc., B. Product Monograph Gadovist 1.0, 2016). * Maier, D. S., Schock, J. & Pfeiffer, F. Dual-energy
micro-CT with a dual-layer, dual-color, single-crystal scintillator. _Opt Express_ 25, 6924–6935, https://doi.org/10.1364/OE.25.006924 (2017). Article ADS PubMed Google Scholar Download
references ACKNOWLEDGEMENTS This work was supported by the DFG Cluster of Excellence Munich-Centre for Advanced Photonics (MAP), the DFG Gottfried Wilhelm Leibniz program, and the TUM
Institute for Advanced Study, funded by the German Excellence Initiative. We thank Dr. Kaye Morgan for her comments. AUTHOR INFORMATION Author notes * Juliana Martins de Souza e Silva
Present address: Institute of Physics, Martin Luther University, Halle-Wittenberg, Germany AUTHORS AND AFFILIATIONS * Chair of Biomedical Physics, Department of Physics and Munich School of
BioEngineering, Technical University of Munich, 85748, Garching, Germany Juliana Martins de Souza e Silva, Julian Utsch, Sebastian Allner, Michael F. Epple, Klaus Achterhold & Franz
Pfeiffer * Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technical University of Munich, 81675, München, Germany Melanie A. Kimm & Franz Pfeiffer *
Institute for Advanced Study, Technical University of Munich, 85748, Garching, Germany Franz Pfeiffer Authors * Juliana Martins de Souza e Silva View author publications You can also search
for this author inPubMed Google Scholar * Julian Utsch View author publications You can also search for this author inPubMed Google Scholar * Melanie A. Kimm View author publications You can
also search for this author inPubMed Google Scholar * Sebastian Allner View author publications You can also search for this author inPubMed Google Scholar * Michael F. Epple View author
publications You can also search for this author inPubMed Google Scholar * Klaus Achterhold View author publications You can also search for this author inPubMed Google Scholar * Franz
Pfeiffer View author publications You can also search for this author inPubMed Google Scholar CONTRIBUTIONS J.M.S.S. and J.U. conceived, designed and performed the experiments; J.U. and S.A.
processed the data; J.M.S.S., J.U., M.A.K., M.F.E., K.A. and F.P. contributed in the manuscript writing. CORRESPONDING AUTHOR Correspondence to Juliana Martins de Souza e Silva. ETHICS
DECLARATIONS COMPETING INTERESTS The authors declare that they have no competing interests. ADDITIONAL INFORMATION PUBLISHER'S NOTE: Springer Nature remains neutral with regard to
jurisdictional claims in published maps and institutional affiliations. ELECTRONIC SUPPLEMENTARY MATERIAL SUPPLEMENTARY INFORMATION RIGHTS AND PERMISSIONS OPEN ACCESS This article is
licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give
appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in
this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative
Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a
copy of this license, visit http://creativecommons.org/licenses/by/4.0/. Reprints and permissions ABOUT THIS ARTICLE CITE THIS ARTICLE Martins de Souza e Silva, J., Utsch, J., Kimm, M. _et
al._ Dual-energy micro-CT for quantifying the time-course and staining characteristics of _ex-vivo_ animal organs treated with iodine- and gadolinium-based contrast agents. _Sci Rep_ 7,